E14000 Electrical Series Auxiliary Inverter
It is about the modernization project of the compressor motor driver and cer motor cooling used in the suburbs trains from GEBZE-HAYDARPAŞA and SİRKECİ-HALKALI of Turkish Rail Directory in TÜVASAŞ since 2005. At the moment there are 26 pieces used in the suburbs.
• There is 2 phases AC input.
• Input voltage: 460 V AC ± %25 (50Hz)
• Inverter Output Voltage: 3 X 390 V (50Hz)
3 X 22 kW (with automatic reserve)
• 32 bit digital PID controller with DC bar trystor and micro processor
• Communication: RS 485 - RS 232
• Working temperature: -25°C / +55°C
• Isolation: The input and output of the transformers are isolated with galvanize.
• 128 troubles can be tracked.
• Advantage of having LOG files
• The system is protected with a thermic –magnetic compact breaker that can be separated from the main power circuit.
• Protections: a. DC bar: Input phase trouble, excessive voltage, excessive intensity, low voltage
. Inverter: Excessive voltage, low voltage, excessive intensity, thermic protection, motor court-circuit, driver feeding trouble
• Protection class: IP-65
|
|
|